- Cart
- |
- Personal Center
- |
1310nm Faraday Rotator Michelson Interferometer 2X2
The Faraday Rotator Mirror (FRM) method is an important solution for suppressing polarization-induced signal fading in interferometric fiber optic sensing systems. In theory, it can completely eliminate polarization fading, but since the rotation angle of the selected FRM is not exactly 45??, residual polarization-induced phase noise will appear in the system. The Faraday Rotator Mirror Michelson interferometer used in the hydrophone can control the difference in length of the two arms to within 1 mm, achieving a low-cost miniaturized desig
Product features:Moisture resistant、 Pressure resistant、 Miniature、 Specially designed for hydrophones simplifies optical design
Part Number:MP-MIM-1310-22-1-SA
Application area:Fiber optic sensing、 Fiber optic hydrophone
Add to Cart Consult Favorite
Parameter
Structure | Unit | 1X2/2X2 |
Working wavelength | nm | 1310/1550 |
Working bandwidth | nm | ±20nm |
Operating power | mW | 500 |
Insertion loss | dB | 3.8 |
Polarization loss | dB | 0.1 |
Split ratio deviation | % | 3 |
Rotation angle | Deg | 45 |
Arm length difference error | mm | 1 |
Fiber model | SMF-28E+ | |
Fiber diameter | um | 9/125 |
Package size | mm | 2.4X25-2.4x12 |
Interference optical path

High temperature storage | Temperature: +85P ±3,0 | 5000 hours |
Low temperature storage | Temperature: -55X) ±3t | 5000 hours |
High temperature and high humidity | Temperature: +85P ±2t, humidity 2=85% | 2000 hours |
Local low temperature cycle | Temperature range: -40P ~ +85Q, temperature change rate N 5t) /min Hot-keeping time: @-40,0, @85: 30min | 1000 cycles |
Temperature shock | Temperature range: -551~ +85*0 Hot-keeping time (@-55*0, @85*0): 30min, high temperature and low temperature conversion time w 5min | 10 times |
Mechanical shock test | Waveform: half sine wave, test direction: 6 directions (3 axes) Peak acceleration: 1500g, pulse duration: 6 ~ 8ms | 5 times in each direction |
Mechanical vibration test | Waveform: sine wave, test direction: horizontal and vertical Acceleration peak: 20g Frequency range: 20 ~ 2000Hz Duration: 4min/time | 4 times in each direction |
Air tightness check | Initial pressure: 0.2MPa, hydrogen tracer gas: 95% ~ 100% Pressure time: 2hrs | Leak rate w 1.0x lO^Pa ·m3/s |
High and low temperature online test | Temperature range: -40 ~ +85P Insulation time (@-40*0, @257, @85*0): 5min | 0.002dBTO |
Ordering Information
MIM-W□□□□-XX-L□□
W□ □□□:wavelength
1310: 1310nm
1550:1550nm
□□:structure
12:1×2
22:2×2
XX: fiber and connector type
SN=SMF-28E Fiber + None
SA=SMF-28E Fiber + FC/APC
SP=SMF-28E Fiber + FC/PC
PP=PM Fiber Fiber + FC/PC
PA=PM Fiber Fiber + FC/APC
L□□:
1=1cm
10=10cm
--
⇪