info@idealphotonics.com
  • 5-meter long optical path miniaturized Mini mid-infrared hollow-core fiber gas absorption cell

    5meter long optical path gas absorption cell can be used for spectral analysis detection. The sturdy and compact gas chamber is coiled with hollow optical fiber, and its arrangement is very simple. In the hollow fiber, the detection beam and the analyte overlap, thus achieving sensitive laser absorption spectroscopy and trace gas and isotope analysis with a sample amount of min.

    Product features:Long optical path design (5 meters); Miniaturized structure;High sensitivity;Vibration resistance; Mid-infrared broadband compatibility

    Part Number:MP-OGC-MIR-5-SS

    Application area:Gas spectral analysis | Environmental monitoring | Industrial process control | Scientific research | Trace gas detection

    Add to Cart Request for Quotation Consult Favorite

    Main parameters
  • Core parameters
  • Wavelength Range Internal Bore Diameter

    3-12um 1.5mm

  • Dimension Drawing
  • General Parameters

    Wavelength Range

    3-12um

    Internal Bore Diameter

    1.5mm

    Path Length

    5m

    Sample Volume

    9ml

    Optical Throughput

    >5%

    Output Divergence 1/2 Angle

    30mRad

    Operating Pressure

    vacuum-15Atm

    Wetted Parts

    Stainless steel

    Silver-lodide

    Window coating


    Variations

    Internal Bore Diameter

    200-1500um

    Path Length

    0.3-5.0m

    Sample Volume

    0.03-9ml

    Window options include wedged and/or AR coated

    Silics: 0.35-0.7um

    BaF2: 0.2-11um

    ZnSe: 2-13um

    Integrated pressure sensors and display(V2)


    1.1.png

     

    Key Features

    Low sample volume: < 10 mL

    Sensitive analysis: < 1 picomole

    Moderate path length: e.g., 5 m

    Compact size

    Incredibly simple and robust alignment

    Various wavelength ranges, including the entire mid-infrared range

     

    Components

    Hollow core fiber with reflective inner coating

    Wedged optical windows (range of materials)

    Swagelok style gas fittings

    Compatible with 30 mm cage mount systems

    Mounting holes for integration onto an optical bench or in a custom housing

     

    1.3.png

     

    Alignment

    The relatively large fiber diameter (ID = 0.2-1.5 mm) and single pass configuration enables obtaining ‘first light” with minimal effort. In some cases, you can collimate your beam and mount your laser on one end and simply put your detector at the other end.


    1.5.png

     

    Versatile Systems

    Gas cells kits can utilize a wide range of Guiding’s hollow core fiber optic waveguides. Options include different sample volumes, path lengths, and wavelength ranges.

     

    Case Study: Measuring NO Gas Using a Gas Cell

    I. Test Instrument Connection and Procedures

    1.6.png


    Procedures:

    1. Install the 5.26 um laser and set it to collimated output.

    2. Connect the other end of the 5-meter gas cell to the MCT detector.

    3. Connect the detector and oscilloscope using a BNC-to-SMA cable.

    Turn on the laser, adjust the current and temperature, and observe the second harmonic absorption spectrum of NO molecules on the oscilloscope.

     

    II. Test Results and Analysis/Verification:

    By adjusting the laser current and temperature, we scanned the laser wavelength across the absorption peak of NO molecules at around 5260 nm, and measured the second harmonic absorption spectrum as shown in the figure below.

    1.7.png


    To verify that the absorption is from NO molecules, we queried the HITRAN database for the following parameters.

    1.8.png


    We can see that the absorption peaks in the database perfectly match the peaks we measured on the oscilloscope. This verifies that the absorption spectrum shown on the oscilloscope is indeed the absorption of NO molecules.

     

    FTIR Gas Cell

    It is also a great solution for FTIR analysis. Standard configurations have excellent transmission from λ= 3 -12 µm (additional wavelength ranges available) with low sample volume requirements (V < 10 mL).

    1.9.png

     

    Species Concentration

    2,3 Butanedione: 99.7 ppm

    Acetaldehyde: 230.2 ppm

    Acetone: 130.8 ppm

    Methane: 259.3 ppm

    Water: -38.8 ppm

    Sulfur dioxide: 2.5 ppm

     

    Trace Gas Analysis

    Versions of our hollow fiber gas cells have been used for a range of trace gas applications.Typical concentration sensitivities are in the 100 ppb range. Considering the small sample volume, this can equate to picomole level sensitivity.

    1.10.png

     

    Isotope Analysis

    Stable isotope analysis such as the ratio of `13C/12C, provide additional information for a range of applications from greenhouse gas attribution to plant microbe interactions. Laser spectroscopy is an excellent means to perform isotope analysis due to unambiguous absorption features from different isotopologues; however, reduced pressure (P ~ 0.01 to 0.1 Atm) is often needed to effectively separate the features by “narrowing” their widths. The Omega is designed to be operated at such pressures and due to small sample volume, can be operated with relatively small pumps.

    1.11.png


    Optional Configurations

    --

    Downloads

    Request for Quotation

    We will reply to all your information about the product in time.

  • Product title: 5-meter long optical path miniaturized Mini mid-infrared hollow-core fiber gas absorption cell
  • Product link: https://www.idealphotonics.com/product/detail/1876.html
    • *Your name:

    • *Phone number:

    • *Your company name:

    • *Email:

    • *Purchase Quantity:

    • *Part Number:

    • Other Requirements:

    • 10+ 10 Years of Experience
    • 50 50 + Countries Bussiness
    • 10000 10k + Diodes sold worldwide
    • 30 30+ Invention patent
    • 10 10+ Advanced Optical Solutions

    ⇪