- Cart
- |
- Personal Center
- |


5-meter long optical path miniaturized Mini mid-infrared hollow-core fiber gas absorption cell
5meter long optical path gas absorption cell can be used for spectral analysis detection. The sturdy and compact gas chamber is coiled with hollow optical fiber, and its arrangement is very simple. In the hollow fiber, the detection beam and the analyte overlap, thus achieving sensitive laser absorption spectroscopy and trace gas and isotope analysis with a sample amount of min.
Product features:Long optical path design (5 meters); Miniaturized structure;High sensitivity;Vibration resistance; Mid-infrared broadband compatibility
Part Number:MP-OGC-MIR-5-SS
Application area:Gas spectral analysis | Environmental monitoring | Industrial process control | Scientific research | Trace gas detection
Add to Cart Request for Quotation Consult Favorite
Wavelength Range Internal Bore Diameter
3-12um 1.5mm

Wavelength Range | 3-12um |
Internal Bore Diameter | 1.5mm |
Path Length | 5m |
Sample Volume | 9ml |
Optical Throughput | >5% |
Output Divergence 1/2 Angle | 30mRad |
Operating Pressure | vacuum-15Atm |
Wetted Parts | Stainless steel Silver-lodide Window coating |
Variations
Internal Bore Diameter | 200-1500um |
Path Length | 0.3-5.0m |
Sample Volume | 0.03-9ml |
Window options include wedged and/or AR coated | Silics: 0.35-0.7um BaF2: 0.2-11um ZnSe: 2-13um |
Integrated pressure sensors and display(V2) | |

Key Features
Low sample volume: < 10 mL
Sensitive analysis: < 1 picomole
Moderate path length: e.g., 5 m
Compact size
Incredibly simple and robust alignment
Various wavelength ranges, including the entire mid-infrared range
Components
Hollow core fiber with reflective inner coating
Wedged optical windows (range of materials)
Swagelok style gas fittings
Compatible with 30 mm cage mount systems
Mounting holes for integration onto an optical bench or in a custom housing



Alignment
The relatively large fiber diameter (ID = 0.2-1.5 mm) and single pass configuration enables obtaining ‘first light” with minimal effort. In some cases, you can collimate your beam and mount your laser on one end and simply put your detector at the other end.

Versatile Systems
Gas cells kits can utilize a wide range of Guiding’s hollow core fiber optic waveguides. Options include different sample volumes, path lengths, and wavelength ranges.
Case Study: Measuring NO Gas Using a Gas Cell
I. Test Instrument Connection and Procedures

Procedures:
1. Install the 5.26 um laser and set it to collimated output.
2. Connect the other end of the 5-meter gas cell to the MCT detector.
3. Connect the detector and oscilloscope using a BNC-to-SMA cable.
Turn on the laser, adjust the current and temperature, and observe the second harmonic absorption spectrum of NO molecules on the oscilloscope.
II. Test Results and Analysis/Verification:
By adjusting the laser current and temperature, we scanned the laser wavelength across the absorption peak of NO molecules at around 5260 nm, and measured the second harmonic absorption spectrum as shown in the figure below.

To verify that the absorption is from NO molecules, we queried the HITRAN database for the following parameters.

We can see that the absorption peaks in the database perfectly match the peaks we measured on the oscilloscope. This verifies that the absorption spectrum shown on the oscilloscope is indeed the absorption of NO molecules.
FTIR Gas Cell
It is also a great solution for FTIR analysis. Standard configurations have excellent transmission from λ= 3 -12 µm (additional wavelength ranges available) with low sample volume requirements (V < 10 mL).

Species Concentration
2,3 Butanedione: 99.7 ppm
Acetaldehyde: 230.2 ppm
Acetone: 130.8 ppm
Methane: 259.3 ppm
Water: -38.8 ppm
Sulfur dioxide: 2.5 ppm
Trace Gas Analysis
Versions of our hollow fiber gas cells have been used for a range of trace gas applications.Typical concentration sensitivities are in the 100 ppb range. Considering the small sample volume, this can equate to picomole level sensitivity.

Isotope Analysis
Stable isotope analysis such as the ratio of `13C/12C, provide additional information for a range of applications from greenhouse gas attribution to plant microbe interactions. Laser spectroscopy is an excellent means to perform isotope analysis due to unambiguous absorption features from different isotopologues; however, reduced pressure (P ~ 0.01 to 0.1 Atm) is often needed to effectively separate the features by “narrowing” their widths. The Omega is designed to be operated at such pressures and due to small sample volume, can be operated with relatively small pumps.

--
Request for Quotation